Distributed generation library resources answer one practical question for US buyers: small-scale solar now carries real load. U.S. generation from rooftop systems smaller than 1 megawatt rose from 18,812 gigawatthours to 92,979 gigawatthours over the last decade, according to the U.S. Energy Information Administration in a report dated 2026-10-16. Growth reached 25 percent in 2022, then the growth rate declined after that year. California produced 34,411 gigawatthours in 2025, or 37 percent of the national small-scale solar total. Capacity in California rose from 18 gigawatts in 2024 to 20 gigawatts in 2025.
What does the distributed generation library show about small-scale solar growth?
Sun-rich states and targeted state incentives shape the small-scale solar map. Arizona supplied 5,795 gigawatthours, over 6 percent of the national total. Texas output rose from 391 gigawatthours in 2016 to 5,408 gigawatthours last year, while Florida rose from 205 gigawatthours in 2016 to 5,198 gigawatthours in 2025.
Desert Southwest output benefits from abundant solar resources. Northeast growth leans on incentives with improving equipment. Roof arrays in those states pair panels with inverters described under distributed generation technologies.
Which CHP prime movers fit small commercial sites?
Packaged reciprocating engines fit many commercial buildings with steady hot-water demand. A CHP system combines a prime mover with a generator, as described by the U.S. Environmental Protection Agency in material last updated 2026-02-19. Heat recovery with electrical interconnection completes the package. The catalog characterizes five commercially available prime movers for CHP.
Biomass with biogas works after added fuel processing, while waste heat to power converts waste heat from an existing thermal process into electric power. Engine packages sized to local electric loads fall under distributed power. Developers match prime movers to thermal profiles before selecting controls. Steam turbines with combustion turbines serve larger thermal hosts beyond packaged sizes.
How do installed small-scale CHP projects perform?
Metered CHP sites show savings tied to fuel choice and continuous thermal demand.
Project figures in the table come from EPA project spotlights last updated 2026-02-19.
| Site | Size | Fuel | Result |
|---|---|---|---|
| Cape Codder Resort and Spa | 335 kW | Natural gas | Serves pools with domestic hot water and black-starts critical loads; installed 2007 with added 85 kW unit in 2009 |
| Oregon Institute of Technology | 2.03 MW | Geothermal hot water | Saves 1,500,000 dollars per year; built in 2010 and 2018 |
| Durham wastewater facility | 1.796 MW | Biogas | Saves 800,000 dollars per year; system installed in 2016 |
Pool heating and campus heating absorb recovered heat across seasons.
What timelines govern distributed resource interconnection?
Federal targets push small systems toward next-day approval and larger systems toward fixed week-scale deadlines. The U.S. Department of Energy roadmap dated 2026-03-18 sets four goals for distribution and sub-transmission interconnection. The goals address transparent data sharing with faster application handling. Fair cost allocation with secure grid operation completes the set.
For 2030 the roadmap targets under 1 day for the smallest systems. Systems from 50 kilowatts to 5 megawatts face under 75 days, while larger systems face under 140 days. Completion-rate targets exceed 99 percent for small systems with 90 percent for medium systems. Large systems target above 85 percent, with public queue data in all 50 states plus Washington DC and territories.
A National Renewable Energy Laboratory guidebook published 2019-04-11 covers application screening with storage interconnection. Upgrade planning with cost allocation gets separate treatment. Utility studies with upgrade fees under state interconnection rules decide local timelines.
Distributed Generation Library FAQs
What does the Distributed Generation Library say about small-scale solar scale?
Rooftop solar now carries meaningful load in several US states. The Distributed Generation Library frames that growth around sunny regions and incentive-driven markets such as New York. California holds the largest share of output and capacity. Buyers use that pattern to shortlist roof orientation with shading review before requesting bids. Local export rules then decide system size and payback.
Which CHP options does the Distributed Generation Library cover for small sites?
Packaged reciprocating engines suit many commercial buildings with steady hot-water demand. The Distributed Generation Library describes CHP prime movers with heat recovery and electrical interconnection. Biomass with biogas needs added fuel processing, while waste heat to power uses heat from an existing thermal process. Developers match engines to electric loads with thermal profiles before choosing controls.
What project results does the Distributed Generation Library document?
Metered sites link savings to fuel choice and continuous heat use. The Distributed Generation Library documents a resort pool system with black-start capability for critical loads. It also documents a campus geothermal plant and a wastewater biogas plant with large annual savings. Operators with similar around-the-clock thermal demand see the strongest fit.
What interconnection timelines does the Distributed Generation Library highlight?
Federal targets favor fast approval for small systems and fixed deadlines for larger ones. The Distributed Generation Library highlights roadmap goals for transparent data sharing with fair cost allocation. Faster application handling with secure grid operation rounds out the federal aims. Utilities still study local feeder impacts before approving upgrade needs.